130
03-0330-0533-11/11-BAT-D291434
Power pack
for hand-held scanner for ATEX Zone 1 and Zone 21
Description
The power pack ensures an intrinsically safe
supply and isolation of the data line for the
BCS 3800
ex
hand-held scanner.
In the Ex area each power pack is available in
three variants:
- AC 100 V up to 250 V
- DC 24 V
- DC 12 V
Both variants are supplied with RS232 and RS422
interface.
In the Ex area in Zones 1 and 21 the power pack
is connected to the BCS 3800
ex
hand-held
scanner by means of a plug-in connection.
Features
No external isolators needed
Direct installation in ATEX Zone 1 and 21
Power pack for hand-held scanner
for RS232 interface/RS422 interface
Explosion protection
Ex protection type ATEX Zone 1 and 21
II 2G Ex eq [ib] IIC T4
II 2D Ex tD21 IP64 T135 °C
-20 °C
< T
a
< +60 °C
Certification
IBExU 09 ATEX 1091
Technical data
Ambient temperature
-20 °C up to +60 °C
Storage temperature
-40 °C up to +60 °C
RS232 interface
up to 15 m
RS422 interface
up to 1000 m
Enclosure material
aluminium
Supply voltage/power consumption
AC 100 V up to AC 240 V/approx. 3.3 W
DC 12 V/approx. 3.7 W
DC 24 V/approx. 4.0 W
Input voltage range
AC 90 V up to AC 264 V, 50 up to 60 Hz
DC 10,8 V up to 13,2 V
DC 18 V up to 30 V
Maximum fault voltage
U
m
= 253 V
Maximum output voltage
U
O
= 5.5 V
Maximum output current
I
O
= 440 mA
Maximum output power
P
O
= 1.25 W
(trapezoidal characteristic curve)
Maximum external capacitance
C
O
= 55 μF
Maximum internal capacitance
C
i
= 2.2 μF
Dimensions (height x length x width)
250 mm x 140 mm x 56 mm
Protection class (EN 60529)
IP 64
Selection chart
Description Order no.
Power pack for the BCS 3800
ex
hand-held scanner
17-21BB-1700
with AC 100 V to 250 V
Power pack for the BCS 3800
ex
hand-held scanner
17-21BB-1701
with DC 24 V
Power pack for the BCS 3800
ex
hand-held scanner
17-21BB-1702
with DC 12 V